SKU
06770-201

SKC HAZ-DUST EPAM 5000

SKC
Add to Wish List Email to a Friend
This is the SKC HAZ-Dust EPAM 5000 which is a portable environmental Particulate Monitor, providing real-time readings and data recordings. Interchangeable size-selective impactors are available for PM10, PM2.5, PM1.0, or TSP. The EPAM-5000 is dedicated for ambient, environmental, and indoor air quality investigations.
£5,573.00
Add to Compare

Product Specification unless deselected above

More Information
Application Dust Sampling
Brand SKC
Available Outside the UK? No

SKC HAZ-DUST EPAM 5000

This is the SKC Haz-Dust EPAM 5000 which is provided with DUSTComm Professional software, a strong battery life allowing for 24 hours of continuous sampling, and a memory capable of storing 15 months of monitoring data.

As a portable microprocessor-based particulate monitor, the HAZ-DUST EPAM 5000 is suitable for use in environmental, ambient and indoor air quality investigations. This monitor is highly sensitive and uses light scattering to measure particle concentration and provide immediate real-time determinations and data recordings of airborne particle concentration in mg/m3. There are interchangeable size-selective sampling heads which allow PM10, PM2.5, PM1.0 or TSP monitoring. The EPAM-5000 has a unique aero-dynamic particle sizing. The 47mm in-line filter holder loaded with the appropriate filter provides concurrent gravimetric sampling. On one battery you can sample for up to 24 hours. You can store up to 15 months of monitoring data. For further analysis you can download the data onto a PC using the included DUSTComm Professional software. Management ready reports and trend analysis can also be generated. The EPAM-5000 can interface with the VDM-7500 wireless video dust exposure monitoring system.

HAZ-Dust EPAM 5000 Features

  • Fast, easy setup
  • Highly sensitive and accurate
  • 0.001 to 20.0 mg/m3 for particles 0.1 to 100 μm
  • Optional 0.01 to 200 mg/m3 range available
  • Accuracy ± 10% to NIOSH Method 0500 using SAE fine test dust
  • High correlation to EPA PM10 methods and TEOM®
  • Ideal for saturation sampling
  • Internal air sample pump for 4.0 L/min flows*
  • Unique aerodynamic particle-sizing real-time sensor
  • Use optional EPA FRM-style cassette holder for gravimetric reference
  • Immediate display and data storage
  • Internal temperature compensation for ambient use
  • Interchangeable size-selective sampling heads for EPA parameters
  • PM10, PM2.5, PM1.0, and TSP
  • Rechargeable lead-acid battery for up to 24-hour operation
  • Continuous monitoring with AC adapter
  • Easy four-key menu-driven operation
  • Stores up to 15 months of data
  • RS232 digital output
  • Easy-to-use DustComm Pro data analysis and reporting software included
  • Portable and compact
  • 6 x 14 x 10 inches (15.2 x 35.6 x 25.4 cm)
  • 12 pounds (5.4 kg)
  • RFI/EMI shielded; CE marked
  • Real-time clock and data display
  • User-programmable start and stop time for unattended data collection
  • On-screen user-selectable sampling parameters retained in memory for quick, easy deployment when sampling parmeters remain unchanged
  • Wireless data transmission option transmits data up to 5 miles


Improved DustComm Pro PC Software provides:

  • Greater flexibility in graphical reports — create and label in new “draw and paint” program
  • Basic trend analysis
  • Live data feed and logging from wireless data transmission
  • Interfaces with the VDM-7500 wireless video exposure dust monitoring system


EPAM 5000 Applications:

  • Quantifying off-site particulate migration
  • Surveying for PM2.5 and PM10
  • Monitoring dust generation during drilling and excavation
  • Evaluating dust suppression and engineering controls
  • Locating and identifying “hot spots”
  • Emergency response and fugitive emissions compliance
  • Determining level of respiratory protection
  • Survey of workplace for OSHA/EPA compliance
  • Evaluating worker exposure to airborne contaminants
  • Dust collector/ventilation system checks
  • Monitoring lung-damaging particles in factories and buildings
  • Complementary instrument for all EPA and OSHA personal and ambient particulate air sampling procedures


Click Here to be Directed to a Glossary of Terms for Air Sampling
Sensing Range 0.001 to 20 mg/m3
0.01 to 200 mg/m3 (optional)
Particle Size Range 0.1 to 100 μm
Precision ± 0.003 mg/m3 (3 μg/m3)
Accuracy ± 10% to NIOSH Method 0500 using SAE fi ne test dust
Sampling Flow Rate 4.0 L/min with variable adjustment
Filter Cassette Holder 47mm
Alarm Output 90 dB at 3ft
Analog Output 0 to 4 VDC
Recording Time 1 sec to 15 mos
Sampling Rate 1 sec, 10 sec, 1 min and 30 min
Data Storage 21, 600 data points
Security Code 4 digit combinations
Memory and Time Storage > 10 years
Data Display Concentration in mg/m3 and TWA, MAX, MIN, STEL, Date and Time
Digital Output RS-232
Operating Temperature -10 to 50 C
Storage Temperature -20 to 60 C
Power Rechargeable Lead-Acid Battery
Operating Time ≥ 24 hrs
Charging Time 10 to 12 hrs
Dimensions (case) 6 x 14 x 10 inches ( 15.2 x 35.6 x 25.4 cm)
Weight 12 lbs (5.4kg)

What's in the Box

  • EPAM 5000 Monitor
  • Specific Cut-Point Impactor
  • Battery and Charger
  • DustComm Professional Software (Windows, 2000, NT, ME and XP compatible)
  • Computer Cable
  • Manual
  • Portable Carry Case

Downloads and Datasheets

Write Your Own Review