SKU
06NLWK

Noise Level Warning System

Castle Group
Add to Wish List Email to a Friend
This is the Noise Level Warning Kit includes the Castle Sonus GA216L Class 2 Logging Sound Level Meter and the GA902 Noise Warning Sign. The GA216L is a logging Class 2 meter and the GA902 can be set to trigger at different dB and therefore taking a measurement first is helpful when setting the GA902. When you buy this kit you receive a 5% discount on the normal price for all of the items individually.
US$2,293.14
Add to Compare

Maximum 45 characters

Product Specification unless deselected above

More Information
Measurement Parameters Leq
Weightings A, C, Z
Application Noise Level Indicators, Noise at Work
Noise Features Data Logging
Brand Castle Group
Available Outside the UK? Yes

Noise Level Warning System

This is the Noise Level Warning Kit includes the Castle Sonus GA216L Class 2 Logging Sound Level Meter and the GA902 Noise Warning Sign. The GA216L is a logging Class 2 meter and the GA902 can be set to trigger at different dB and therefore taking a measurement first is helpful when setting the GA902. When you buy this kit you receive a 5% discount on the normal price for all of the items individually.


Castle Sonus GA216L Class 2 Logging Sound Level Meter

This is the Sonus GA216L Class 2 Logging Sound Level Meter which is a pocket sized sound level meter and brings simplicity and power to the worlds of Environmental Sound Monitoring and Noise at Work. The GA216L is the top of the Castle Pocket Range of Sound Level Meters. It is an Environmental and Noise at Work Sound Meter which boasts a combined integrating sound level meter with full data-logging capability.


GA902 Noise Warning Sign

The GA902 Noise Warning Sign activates only when the noise exceeds a pre-set level allowing exposed workers to wear ear defenders only when absolutely necessary, as ear defenders are often a less than popular safety measure. According to industrial safety law, areas subject to hazardous noise must be clearly defined, and workers notified of the danger. In many cases, the noise hazard is intermittent and that's precisely the situation for which the GA902 was designed. This meter is suitable for most industrial situations as it has a rugged construction. The warning text is generally supplied to EC requirement but alternative languages and graphics are available to order. There is an optional remote microphone which enables the sign itself to be in a prominent position while the microphone can be placed closer to a major noise source, order as GA902R. You can fit the optional Remote-Beacon which greatly increases the warning impact, especially in a large area. It is a self-contained unit housing its electronics in a tough case and can be easily installed and set for action. The front panel text is available as standard in EC or USA forms, but it can be ordered in a variety of colours and in any language. The front panel is completely blank when idle but it is brilliantly lit when activated to give an easily noticed warning. It is a complete system so outputs from the master unit can also trigger other external devices such as machines or process cut-off actuators. Custom screen text can be obtained where necessary.

Castle Sonus GA216L Class 2 Logging Sound Level Meter

Standards IEC61672-1-2002 (Sound Level Meters) IEC61252-1993 (Personal Sound Exposure Meters) Level ranges:
RANGEDISPLAY RANGELINEAR RANGEPEAK RANGE
30-10029 – 101dB30 – 100dB40 – 103dB
50-12059 – 121dB50 – 120dB60 – 123dB
70-14069 – 141dB70 – 140dB80 – 143dB
Linear Operating Range 70dB
Detector Characteristics RMS and Peak
Frequency Weighting ‘A’, ‘C’ & ‘Z’ Weighted in Accordance with IEC 61672-1-2002 Combinations of ‘A’, ‘A’&’C’ simultaneous or ‘A’&’Z’ simultaneous available for Leq, Lmax and Pmax
Time Weighting ‘Slow’, ’Fast’ and ‘Impulse’ in Accordance with IEC 61672-1-2002
Exchange Rate 3dB, 4dB or 5dB
Criterion Level 75dB, 80dB, 85dB or 90dB
Threshold Level -5dB, -10dB or OFF
Peak 3dB above top of selected range
Display Custom alphanumeric LCD, digit size 7mm x 5mm
Memory 4800 Data Intervals Maximum
Microphone/ Preamplifier ACO 7146A pre-polarised ½” condenser microphone, 25mV / Pa
Calibration 91.0 to 120.0dB @ 1KHz
Batteries 1 x PP3 (9V) Approximately 12 hours continuous use
Operating Temperature Operating Range: -10 to + 50ºC
Humidity Effect: < 0.5dB from 25% to 90% RH
Vibration No effect on instrument

GA902 Noise Warning Sign

Measuring Range 75 dB to 112.5dB steps switch selectable 2.5dB variable calibration control (factory set)
Trip Time User Adjustable 5 to 30 seconds
Controls Push to Test button Mains Power "on" indicator
Detector Characteristic: Averaging
Frequency Weighting 'A' in accordance with IEC651 Type 2
Time Response Slow Response (1000mS)
Microphone (standard) Built in Castle 1/2" electret
Microphone (Remote) Pre-polarised 1/2" (12.7mm) Condenser Microphone Sensitivity 12mV/Pa Capacitance 15pF; Preamp output impedance 550R Cable Mounted
Outputs Switched AC power feed for external beacon; Change-over relay contact sets
Power 220V to 240V AC,50Hz/60Hz or 100V to 120V AC,50Hz/60Hz (Select on order)
Illumination Two 8w, 12" fluorescent tubes
Dimensions Overall: 520 x 200 x 120
Viewable Screen Area 450 x 190

What's in the Box

1 x Castle GA216L SONUS Safety/Environmental Data-logging Sound Meter Class 2 

 1 x GA902 Noise Activated Warning Sign (Specify 110v or 240v)

Downloads and Datasheets

Castle Sonus GA216L Class 2 Logging Sound Level Meter

Datasheet GA216L SONUS Sound Meters Manual Sonus Operating Manual GA116L and GA216L Quick Start Guide
Write Your Own Review
You're reviewing:Noise Level Warning System