SKU
06BSWA308

BSWA308 Class 1 Sound Level Meter

Add to Wish List Email to a Friend
This is the BSWA308 Class 1 sound level meter which complies with IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997. The linearity range is 20dBA~134dBA and it has a single range to cover 123dB dynamic range. They have a frequency weighting A/B/C/Z and a time weighting of fast/slow/impulse. There is a 3 profile calculation in parallel with different frequency/time weighting and 14 custom define measurement. This meters come as standard with 1/1 Octaves, however, you have the option of 1/3 Octaves.
US$1,861.93
Add to Compare

Product Specification unless deselected above

More Information
Application Health and Safety
Measurement Parameters Leq, Peak, Lmax, Lspl, Lmin
Class Class 1
Weightings A, C, Z
Application Noise at Work
Noise Features 1/3 Octaves, 1/1 Octaves, Data Logging
Brand BSWA
Boxed Weight (kg) 0.7
Available Outside the UK? Yes

BSWA308 Class 1 Sound Level Meter

This is the BSWA308 Class 1 sound level meter which complies with IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997. The linearity range is 20dBA~134dBA and it has a single range to cover 123dB dynamic range. They have a frequency weighting A/B/C/Z and a time weighting of fast/slow/impulse. There is a 3 profile calculation in parallel with different frequency/time weighting and 14 custom define measurement. This meters come as standard with 1/1 Octaves, however, you have the option of 1/3 Octaves. It will calculate SPL, LEQ, Max, Min, Peak, SD, SEL and E and there is LN statistics and time-domain curve display.

The BSWA308 has user define integral period measurement and high speed ARM with FPU (Float Point Unit) to achieve wide dynamic range and low noise floor as well as 4G MicroSD card (TF card) mass storage. There is a RS-232 remote control port and a mini thermal printer for measurement data print.

Please Note: The Peak C Range of this instrument is 45dB(A)~137dB(A)


Features

  • Single Chip High Speed ARM with FPU
  • White Backlight LCD
  • Integral Period from 1s~24h
  • 0.1s, 0.2s, 0.5s logger step added
  • 5 templates to save user setting
  • B-Weighting added to meet ANSI standard
  • Automatic Power on with external supply, ease of integration
  • USB Port Function Implemented
  • Update Firmware via USB (also power supply)
  • Timer Feature Support Auto Measurement
  • Internal GPS (option) with GPS Timing
  • Single Range to Cover 123dB dynamic range
  • Reduce the Noise Floor
  • Upper Limit of Measurement: 136dBrms/139dBpeak (40Mv/Pa)


Applications

  • Basic Noise Measurement
  • Environmental Noise Assessment
  • Product Quality Check
  • Evaluation of Noise Reduction Engineering
Accuracy Class 1 / Type 1
Standard GB/T3785.1-2010, GB/T3785.2-2010, IEC60651:1979, IEC60804:2000, IEC61672-1:2013, ANSI S1.4-1983, ANSI S1.43-1997
Octave Real-time 1/1 Octave: 8Hz~16kHz Optional Real-time 1/3 Octave: 6.3Hz~20kHz GB/T 3241-2010, IEC 61260-1:2014 ANSI S1.11-2004. Base 10 system
Supplied Microphone MPA231T: 1/2” prepolarized measurement microphone, Class 1. Sensitivity: 50mV/Pa. Frequency Range: 6.3Hz~20kHz.
Mic Interface TNC Connecter with ICCP Power Supply (4Ma/24V)
Detector/Filter All Float-Point Digital Signal Processing (Digital Detector and Filter)
Integral Period 1s-24h User Define Integral Period. Repeat Time: infinite, 1~9999
Measurement Functions LXY(SPL), LXeq, LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN. Where X is the frequency weighting: A, B, C, Z; Y is time weighting: F, S, I; N is the statistical percentage: 1~99.
24h Measurement Automatic Measurement and Log the History Data
Frequency Weighting Parallel A, B, C, Z (It can also be applied to 1/1 and 1/3 Octave)
Time Weighting Parallel F, S, I and Peak Detection
Self-Noise Sound: 18dB(A), 23dB(C), 31dB(Z) Electrical: 11dB(A), 16dB(C), 21dB(Z)
Upper Limit 134dB(A) Increase to 154dB(A) with 5mV/Pa Microphone
Frequency Response 6.3Hz~20kHz
Linearity Range 20dB(A)~134dB(A)
Dynamic Range 123dB (11dB(A)~134dB(A))
Peak C Range 45dB(A)~137dB(A)
Range Setting Single Range
Resolution 24Bits
Sampling Rate 48kHz (Sampling Interval for LN: 20ms)
Noise Curve Time Domain Noise Curve Display. Duration Time: 1min, 2min, 10min
LCD Display 160x160 LCD with White Backlight, 14 step contrast level
Mass Storage 4G MicroSD Card (TF Card)
Post-Processing Post-processing software VA-SLM can read, analyze and generate reports of store data
Export Data Directly connect to the computer to read the memory card (USB disk)
Output AC (max 5VRMS output), DC (10mV/dB), RS-232 serial interface and USB virtual serial port
Alarm User Define Alarm Threshold. LED Indicate the Alarm Status
Power Supply 4x1.5V alkaline batteries (LR6/AA/AM3), sustainable use of more than 10 hours. It also can be supply by external DC power (7V-14V 500mA) and USB power (5V 1A)
RTC Built-in backup battery has been calibrated at factory to the error <30s in 30days (<10ppm, 25?C). It can keep RTC running when replacing the main batteries. GPS timing function available (option with GPS module)
Firmware Update Update firmware via USB port
Conditions Temperature: -10℃~ 50℃. Humidity: 20% ~ 90%RH
RT Temperature Real-Time Temperature Display on the Main Screen
Size (mm) W70 x H300 x D36
Weight Approx 620g, including 4 Alkaline Batteries

What's in the Box

Whats in the Box?

  • Class 1 1/1 Octave Sound Level Meter
  • Type 1 micophone
  • 4G microSD card
  • Carrying Case
  • a 9-cm windscreen
  • 4 AA batteries
  • Calibration Chart
  • Frequency Weighting of Parallel A, B, C, and Z
Write Your Own Review
You're reviewing:BSWA308 Class 1 Sound Level Meter
We found other products you might like!