TPI 709R Flue Gas Analyser Kit - has all the features of the 708 PLUS high resolution 0.001 in H20, differential manometer for high efficiency and oil equipment, Measures CO, and temperature and Calculates CO2, efficiency, excess air, and CO air free. The carbon monoxide sensor used in this TPI combustion efficiency analyser features an on-board filter capable of filtering NO (nitric oxide), NO2 (nitrogen dioxide) and NOX (combination of NO and NO2) to prevent cross sensitivity errors. Use to test flue gases in gas and oil fired equipment including high efficiency furnaces and condensing boilers. Measure CO, O2, and stack temperature.

All TPI analyzers feature quick and simple set up. Fast purge and the ability to perform fuel selection during start up enable tests to be performed quickly without requiring extra set-up time after initial start up. TPI analyzers also use the last selected fuel as the default setting. This feature prevents the need to perform fuel selection every time the analyzer is turned on

The carbon monoxide sensor used in TPI combustion efficiency analyzers feature an on-board filter capable of filtering NO (nitric oxide), NO2 (nitrogen dioxide) and NOX (combination of NO and NO2) to prevent cross sensitivity errors.

Features

Calculates combustion efficiency
Pump driven for fast response
Will not shut off if 15 ppm CO is present for increased safety
Ten selectable fuels: Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
Optional A740 IR printer available for hard copies of test results
Built-in differential thermometer
Store function to save up to 50 readings
Type K Thermocouple
Quick reaction spring loaded open wire sensor
Temperature range: -50 to +250°C
Clamps on to pipes up to 30mm diameter
1000mm polyurethane lead

Whats in the box

TPI 709R Instrument
Rubber Boot
Soft Carrying Case
Sampling Probe (c/w Type “K” Thermocouple)
In-Line Water Trap Bowl Filter (c/w Spare Particle Filter)
Battery Charger
Mini In-Line Pump Protection Filter (c/w 5 spare filters)
Exhaust Spigot (removable)
Pressure Tubing (2 x 1 metres)
GK11M Air Probe
Instruction Manual

US$738.65
Add to Compare

Product Specification unless deselected above

More Information
Available Outside the UK? Yes
Brand TPI
Measure CO, O2 & Flue Temperature
 Calculate CO2, CO/CO2 Ratio, Efficiency & Excess Air
 Dual Input Differential Manometer – Great for performing Standing Pressure or Let By/Tightness Tests
 (Timed Let By/Tightness Test available on the 716 – click here to view the 716)
 Dual Input Differential Thermometer – Ideal for measuring & recording Flow & Return Temperatures
 Ambient CO Analysis (Timed BS7976 CO Build Up Test available on the 716 – click here to view the 716)
 6 Year Warranty* (* subject to annual service being carried out each year by TPI or one of its approved
 local service centres)
 Diagnostic software & technical helpline combine to save time and money on reduced downtime as many
 of the reported faults can be rectified over the phone keeping you and your instrument working
 Unique external water trap filtration system as standard on all kit options preventing loss of downtime or
 additional costs due to potentially damaged sensors caused by water ingress
 10 Fuel options including Wood, Light & Heavy Oil, LPG and Natural Gas
 Will not shut off if CO ppm is above 15ppm for increased safety for both the user and the instrument
 Unique in-line pump protection filter fitted as standard across all kits preventing loss of downtime or
 additional costs due to a potentially damaged pump caused by dust/dirt ingress
 Protective rubber boot as standard to protect the FGA
 Re-Chargeable battery housed in a separate compartment ensuring no heat transfer when using on the
 mains to affect gas readings
 All kits come supplied in a soft carry case to protect not only the FGA but all of your accessories
 Capability of sending Live or Stored readings to an optional IR Printer (Pin Protected Company Details
 can be part of the Header of the Print Out with the 716 – click here to view the 716)

What's in the Box

TPI 709R Analyser
Rubber Boot (A765) 1 each installed on analyser
Soft Carrying Case (A768)
Sampling Probe (c/w Type “K” Thermocouple)
In-Line Water Trap Bowl Filter (c/w Spare Particle Filter)
Battery Charger (A766)
Mini In-Line Pump Protection Filter (c/w 5 spare filters)
Exhaust Spigot Removable (A764)
Pressure Tubing (2 x 1 metres)
GK11M Air Probe
Instruction Manual

A740 IR Printer